CODE IDENTIFICATION: S
PROPONENT:: Stuart Adams
REPRESENTING:: self
CODE IDENTIFICATION label::
CHAPTER/SECTION:: Appendix N, Section N104.1.2
PROPOSED TEXT:: N104.1.2 Structural plans, specifications and engineering details. Where approval of the structural requirements of the replicable design is sought, the submittal documents shall include details for each wind region, seismic design category, Special Flood Hazard Area (SFHA), and climate zone for which approval is sought; and shall include the following:



1. Signed and sealed structural design calculations that support the member sizes on 
the drawings.




2. Design load criteria, including: frost depth, live loads, snow loads, flood loads, wind loads,
earthquake design date, and other special loads.




3. Details of foundations and superstructure.




4. Provisions for special inspections.


REASON/SUBSTANTIATION/BIBLIOGRAPHY:: The Commonwealth of Puerto Rico includes numerous Special Flood Hazard Areas (SFHA), in which replicable design building programs could be implemented following Hurricanes Irma and Maria. Including details appropriate to the SFHA in the construction documents provides the design parameters necessary for the approved agency per N105.1 to determine compliance with the 2018 International Building Code and Planning Regulation 13. This furthers the intent of Appendix N to give jurisdictions a means of streamlining their document review process while verifying code compliance. FEMA P-339 Hurricane Georges BPAT stated that "The non-engineered, self-built homes the BPAT observed performed poorly during the hurricane... A lack of compliance and enforcement of Planning Regulation 7 has resulted in a large number of buildings incapable of carrying the prescribed load." The ongoing FEMA Mitigation Assessment Team efforts include observations on informal construction and the importance of using proper design parameters.

COST IMPACT:: Special Flood Hazard Area (SFHA) considerations are necessary for proper hazard-resistant design and construction to comply with the 2018 International Building Code. Limited cost impact for documentation submittal and review is assumed.

Myself: No
Other: No
PROPOSAL NUMBER #: IBC-S
field4:
myself: Yes
Firma: Stuart Adams
Please type or print full name: Stuart Adams
Company: Stantec
Entity Represented: self
Contact info: Phone: 2026009019
e-mail: stuart.adams@stantec.com
Date signed: 4/20/2018